Our references Municipalities
Back
Plouguenast | 22 | France

Capacity in IE : 1 800
Year of construction : 2007
Project owner : Commune de Plouguenast
Consultant : SETUR

TYPE OF TREATMENT

Water treatment
- Aeration basin 418 m³ with air diffusers
- Deaerator
- Floating matters storage tank
- Scraper settling tank Ø 13,5 m
- Phosphate removal

Sludge treatment
- Sludge recirculation
- Sludge dehydration by draining screw
- Sludge storage tank 500 m³

TECHNICAL DATA OF PLANT

Capacity of treatmentTreated water discharge standards
Capacity of treatment1 800 IE
Daily volume400 m³/d
Peak flow35 m³/h
Biological oxygen demand (BOD5)108 kg/d15 mg/l
Chemical oxygen demand (COD)216 kg/d50 mg/l
Suspended solids162 kg/d30 mg/l
Total Kjeldahl nitrogen25 kg/d15 mg/l
Total nitrogen25 kg/d15 mg/l
Total phosphorus5,4 kg/d5 mg/l