Our references Industrial wastewater
MATTUSSIÉRE ET FOREST | DOMÈNE | 38 | FRANCE

Capacity in IE : 37 800
Capacity in m³ per day : 7 680
Activity : Paper mill
Year of construction : 1992

TYPE OF TREATMENT

Water treatment
- Coagulation
- Flocculation
- Settling tank
- Aeration basin
- Settling tank

Sludge treatment
- Belt filter press

TECHNICAL DATA OF PLANT

Capacity of treatmentTreated water discharge standards
Daily volume7 680 m³/d
Peak flow320 m³/h
Pollution load37 800 IE
Biological oxygen demand (BOD5)2 266 kg/j100 mg/l
Chemical oxygendemand (COD)5 148 kg/j300 mg/l
Suspended solids9 658 kg/j100 mg/l

The Inhabitant Equivalent (IE) is a notion used in sanitation to evaluate the size of waste water treatment plants, it corresponds to an estimate of pollution caused by the "inhabitant equivalent" defined thus :
- 60 g/inhabitant/day for DBO5
- 90 g/inhabitant/day for suspended matter
- 15 g/inhabitant/day for total nitrogen
- 4 g/inhabitant/day for total phosphor