Torraspapel Motril | MOTRIL | ESPAGNECapacity in IE : 70 000
Activity : Paper mill
Year of construction : 1991
TYPE OF TREATMENT
Water treatment- Coagulation
- Flocculation
- Settling tank
Sludge treatment
- Belt filter press
TECHNICAL DATA OF PLANT
| Capacity of treatment | Treated water discharge standards | |
| Daily volume | 2 100 m³/d | |
| Pollution load | 70 000 IE | |
| Biological oxygen demand (BOD5) | 4 200 kg/j | 30 mg/l |
| Chemical oxygendemand (COD) | 9 500 kg/j | 125 mg/l |
| Suspended solids | 390 kg/j | 35 mg/l |
| Total Kjeldahl nitrogen | 1 340 kg/j |
The Inhabitant Equivalent (IE) is a notion used in sanitation to evaluate the size of waste water treatment plants, it corresponds to an estimate of pollution caused by the "inhabitant equivalent" defined thus :
- 60 g/inhabitant/day for DBO5
- 90 g/inhabitant/day for suspended matter
- 15 g/inhabitant/day for total nitrogen