Our references Industrial wastewater
Back
Graindorge | Livarot | 14 | FRANCE

Capacity in IE : 10 000
Capacity in m³ per day : 400
Activity : Food-processing industry
Category : Cheese factory
Year of construction : 2002

TYPE OF TREATMENT

Water treatment
- Biological treatment
- Settling tank

Sludge treatment
- Gravity belt thickener
- Sludge storage tank

TECHNICAL DATA OF PLANT

Capacity of treatmentTreated water discharge standards
Daily volume400 m³/d
Peak flow70 m³/h
Pollution load10 000 IE
Biological oxygen demand (BOD5)610 kg/j20 mg/l
Chemical oxygendemand (COD)930 kg/j90 mg/l
Suspended solids125 kg/j30 mg/l
Total Kjeldahl nitrogen27 kg/j15 mg/l
Total phosphorus27 kg/j

The Inhabitant Equivalent (IE) is a notion used in sanitation to evaluate the size of waste water treatment plants, it corresponds to an estimate of pollution caused by the "inhabitant equivalent" defined thus :
- 60 g/inhabitant/day for DBO5
- 90 g/inhabitant/day for suspended matter
- 15 g/inhabitant/day for total nitrogen
- 4 g/inhabitant/day for total phosphor

Télécharger au format PDF