Our references Industrial wastewater
Belma | Agadir | morocco

Capacity in IE : 42 000
Capacity in m³ per day : 500
Activity : Food-processing industry
Category : Fish cannery
Year of construction : 2008

TYPE OF TREATMENT

Water treatment
- Screening
- Buffer tank
- Coagulation
- Flocculation
- Flotation

Sludge treatment
- Sludge centrifugation

TECHNICAL DATA OF PLANT

Capacity of treatmentTreated water discharge standards
Daily volume500 m³/d
Peak flow25 m³/h
Pollution load42 000 IE
Biological oxygen demand (BOD5)2 500 kg/j1 000 mg/l
Chemical oxygendemand (COD)5 000 kg/j2 000 mg/l
Suspended solids1 300 kg/j500 mg/l
Total Kjeldahl nitrogen300 kg/j350 mg/l
Total phosphorus200 kg/j mg/l

The Inhabitant Equivalent (IE) is a notion used in sanitation to evaluate the size of waste water treatment plants, it corresponds to an estimate of pollution caused by the "inhabitant equivalent" defined thus :
- 60 g/inhabitant/day for DBO5
- 90 g/inhabitant/day for suspended matter
- 15 g/inhabitant/day for total nitrogen
- 4 g/inhabitant/day for total phosphor

Télécharger au format PDF