Our references Domestic wastewater
Montfort le Gesnois | 72 | France

Capacity in IE : 4 000
Year of construction : 2004
Project owner : Commune de Montfort le Gesnois
Consultant : IRH / D.D.E.

TYPE OF TREATMENT

Water treatment
- Storm water tank 320 m³
- Aeration basin 800 m³
- Air diffusers
- Phosphate removal
- Deaerator
- Scraper settling tank Ø 19,8 m

Sludge treatment
- Sludge recirculation
- Sludge thickener
- Gravity belt thickener
- Sludge storage tank 900 m³

TECHNICAL DATA OF PLANT

Capacity of treatmentTreated water discharge standards
Capacity of treatment4 000 IE
Daily volume1 250 m³/d
Peak flow110 m³/h
Biological oxygen demand (BOD5)240 kg/d25 mg/l
Chemical oxygen demand (COD)480 kg/d90 mg/l
Suspended solids360 kg/d35 mg/l
Total nitrogen50 kg/d15 mg/l
Total phosphorus8 kg/d2 mg/l

The Inhabitant Equivalent (IE) is a notion used in sanitation to evaluate the size of waste water treatment plants, it corresponds to an estimate of pollution caused by the "inhabitant equivalent" defined thus :
- 60 g/inhabitant/day for DBO5
- 90 g/inhabitant/day for suspended matter
- 15 g/inhabitant/day for total nitrogen
- 4 g/inhabitant/day for total phosphor

Télécharger au format PDF