Kesckemet | HungaryCapacity in IE : 250 000
Capacity in m³ per day : 48 000
Year of construction : 1994
Project owner : City of Kesckemet
Consultant : Melyepterv
TYPE OF TREATMENT
Water treatment- Screnning
- 4 activation tank of 3000 m³ with aeration by air diffusers
- 3 blowers 200 kW
- Dearator
- 4 settling tank Ø 36 m
- Chlorination
Sludge treatment- 3 digester of 2460 m³ with cogeneration
- 2 belt filter press
TECHNICAL DATA OF PLANT
| Capacity of treatment | Treated water discharge standards | |
| Capacity of treatment | 250 000 IE | |
| Daily volume | 48 000 m³/d | |
| Peak flow | 2 667 m³/h |
| Biological oxygen demand (BOD5) | 14 400 kg/d | 25 mg/l |
| Chemical oxygen demand (COD) | 32 000 kg/d | 120 mg/l |
| Suspended solids | 12 000 kg/d | 30 mg/l |
| Total Kjeldahl nitrogen | 2 400 kg/d | 30 mg/l |
| Total nitrogen | 2 400 kg/d | |
| Total phosphorus | 576 kg/d |
The Inhabitant Equivalent (IE) is a notion used in sanitation to evaluate the size of waste water treatment plants, it corresponds to an estimate of pollution caused by the "inhabitant equivalent" defined thus :
- 60 g/inhabitant/day for DBO5
- 90 g/inhabitant/day for suspended matter
- 15 g/inhabitant/day for total nitrogen
- 4 g/inhabitant/day for total phosphor